City
Services - Public Works
Property
Maintenance Inspections
Scope
of Inspection || What
Inspectors Look For ||
Online Application Forms || What
To Expect During An Inspection ||
Private
Inspectors || What
If There Are Code Deficiencies? ||
More
Information || Number
of Occupants Allowed || Public
Works Home
||
What is
the scope of a Kirkwood Property Maintenance Inspection?
The inspection is a minimum property
maintenance inspection made exclusively for the use of the City
in determining the premises’ compliance with the City’s
Property Maintenance Code for occupancy.
The inspection is limited to observations
readily visible without moving or removing any item. Confined
spaces such as attics and crawl spaces are not inspected.
Furnishings are not moved. Concealed, internal, or hidden damage
or defects may not be observed.
The condition and operation of the heating,
air conditioning, and water heater systems are not checked.
The overall condition of the roof and
roofing materials is not inspected.
The electrical service panel cover is not
removed, and electrical circuits are not checked.
What
do Kirkwood Housing Inspectors look for?
The Inspector performs a visual inspection
of the premises based on the Kirkwood Property Maintenance Code.
The Building Commissioner’s Office then issues a report
detailing code violations, which require correction prior to the
issuance of a new occupancy permit. The following is a partial
list of the more common items which are included in the
inspection:
Exterior Premises
- General Sanitation - No accumulation of rubbish, garbage,
tree limbs or yard waste
-
Drainage - No stagnant water or
blocking of drainage course
-
Driveways/Sidewalks - Good repair
-
Weeds/Dead Trees/Dead & Dangerous
Limbs - Cut or remove
-
Rat Infestation - Remove
-
Exhaust Vents to Outside - Good repair
-
Sheds, Garages, Fences, Retaining
Walls, Swimming Pools - Good repair, safe condition
-
Unlicensed Motor Vehicles/Trailers -
License or remove
-
Sidewalks - Good repair
Exterior Structure
-
Exterior Structure - Good repair,
structurally sound, sanitary
-
Exterior Painting - no peeling,
flaking, or chipped paint
-
Street Numbers - If missing or new,
must be 4” high. Existing must be easily visible
-
Foundation Walls - Plumb, fill, or
repair cracks and breaks
-
Exterior Walls - No holes, breaks,
loose or rotting material; weather proofed and properly
coated
-
Roof - Tight, sound, does not admit
rain, clear of limbs, branches
-
Decorative Features - Good repair/safe
condition
-
Overhangs (canopies, awnings, etc.) -
Good repair, safe condition
-
Chimneys - Good repair, safe condition
-
Handrails - Firmly fastened, good
condition
-
Window and Door Frames - Good repair,
weather tight glazing, crack and hole free, operable windows
capable of holding in open position with provided hardware
-
Insect Screens - Properly maintained
-
Doors and Hardware - Good repair,
operable
Interior Structure
-
Interior Structure - Good repair,
structurally sound, sanitary condition
-
Structural Integrity - All structural
members
-
Interior Surfaces - Good, clean,
sanitary condition, no peeling paint, cracked or loose
plaster, damaged wood, etc.
-
Stairs and Railings - Good repair
-
Handrails and Guardrails - Good repair
-
Rubbish and Garbage - No accumulation
-
Insect and Rat Infestation –
Extermination required if found
-
Bathroom Ventilation - All bathrooms
shall have openable windows or a mechanical ventilation
system.
Plumbing
-
Plumbing Fixtures, Pipes, and System -
Working order, free from leaks or defects, maintained as
safe, sanitary and functional; properly installed and
maintained (properly trapped, vented)
-
Backflow Preventer & Vacuum Breaker
- Required for lawn sprinkler systems and swimming pool hose
bibs
Electrical and
Mechanical
-
Heat Supply - Required in good repair,
safe condition
-
Mechanical Equipment and Fireplaces -
Properly installed, safe condition
-
Fuel Burning Equipment - Good repair,
safe condition, properly installed, properly connected to
chimney or vent
-
Garage installations require proper
fire protection and adequate combustion air
-
Mechanical Safety Controls -
-
Working
Condition
-
Gas
shut-off adjacent to appliances
-
Minimum Electrical Service - 60 amp, 3
wire
-
Electrical Service and Systems -
Hazardous conditions must be corrected such as:
-
Low hanging
electrical wires - when grade has been elevated or structure
(fence, pool, shed) is under wire, then wire must be raised
or relocated
-
Improper
wiring or installation
-
Deterioration or damage to wiring,
fuses, panel, etc.
-
Flush or
semi-flush mounted floor receptacle outlets, unless provided
with an approved
listed cover
-
Extension
cords for other than short term, temporary use
-
Lamp cord used
as permanent wiring
-
Conductor
supported pendant switches or conductor supported pendant
lighting fixtures
-
Loose or
hanging wires
-
Frayed or bare
wires
-
Open terminal
fixtures are prohibited
-
Outlets used
by washing machines, dryers, sump pumps must be on a
grounded three-wire
circuit within four feet of the appliance (No extension
cords or plug adaptors)
-
Grounded-type
receptacles which are improperly or inadequately grounded.
-
Garage door
openers must have receptacle within three feet, (No
extension cords or plug
adaptors) or properly hard wire
-
Minimum of two
electrical outlets required in each habitable room
-
Minimum of one
electrical outlet required in every bathroom
-
Light fixture
required in halls, stairways, water closets, bathrooms,
laundry rooms, and
furnace rooms
-
GFI required
on all receptacles within six feet of water source, in
garage, on exterior, and in unfinished basement, except
those for dedicated appliances.
Safety Items
-
Graspable Handrails - A flight of
stairs with more than four risers shall have a graspable
handrail on one side, 30" to 42" above tread (except in yard
areas which are not part of the egress to a structure.)
-
Guardrails - Stairs, landings, decks,
balconies, or any walking surface over 30” above grade shall
have guardrails with intermediates
-
Swimming Pool Guards/Fences -
-
Fence and gate - Good repair and working order
-
Minimum 48”
fence height
-
Gates -
Self-latching, self-closing, with latch 48” above ground or
pool side at highest point on gate
-
No electrical
wires over pool or within 10’ of outer edge unless 22.5’ or
more above water
surface
-
Doors - Lock must be operable from egress
side without key or special knowledge
-
Emergency Escape - Sleeping rooms must have
openable window or exterior door; or two means of approved
egress from room
-
Fire Resistance Ratings - Must be
maintained; no penetrations in fire rated walls unless
penetration is fire rated
-
Attached Garages -
-
Beneath dwelling - 5/8” gypsum board on garage side, on
all ceilings, partitions, wall between house
and garage, and structural members, no penetrations unless fire rated;
1-3/4” solid core door
-
Attached to
Dwelling - 1/2” gypsum board on garage side between house and garage; 1-3/4”
solid core door - No penetrations greater than 4” diameter and
no more than 3
penetrations
-
Smoke Detectors - In each bedroom; in
the vicinity of the bedrooms, and on each level, including
the basement.
What
to expect during the inspection
-
The typical inspection will take 30 minutes
to 2 hours depending upon the size and condition of the
property.
-
Please confine your pet during the
inspection.
-
You are welcome to go with the inspector if
you wish.
-
The inspector will be happy to answer your
questions, time permitting.
-
A detailed verbal or written report cannot
be issued at the time of the inspection. A written report will
be mailed to the person requesting the inspection in a few days.
Anyone can obtain a copy of the report at City Hall in the
Building Commissioner’s Office after the
report is ready.
What
if there are code deficiencies?
A few days after the inspection, the City
will issue a report listing the results to the person who
requested the inspection. In accordance with Missouri Law, the
inspection report becomes a public record and will be provided
to the public upon request. When the problems
are remedied, you will need to contact the Building
Commissioner’s Office for a re-inspection at (314) 822-5823.
Some of the corrective work which is
required as a result of the Property Maintenance Inspection may
require building, electrical, mechanical, or plumbing permits.
These are separate permits, and this work must be performed by
Kirkwood Licensed Contractors. The Housing Inspector may not
approve such corrective work until it is inspected and approved
by the Building Inspector, Electrical or Mechanical Inspector,
or the Plumbing Inspector, in accordance with the type of permit
that was issued.
What
about private inspectors?
It is recommended that home buyers have an
inspection from a private inspection company. Private
inspections can give the buyer a detailed report of the home’s
physical and operational condition, and can help the buyer
render an opinion on the condition of the house.
What
number of occupants is allowed?
A residential dwelling is limited to the
number of occupants by the following two conditions:
|
MINIMUM
AREA REQUIREMENTS
|
|
SPACE
|
MINIMUM
AREA IN SQUARE FEET
|
|
|
1-2
PEOPLE
|
3-5
PEOPLE
|
6
OR PEOPLE
|
|
Living Room (1)
|
No
requirements
|
120
|
150
|
|
Dining Room (1)
|
No
requirements
|
80
|
100
|
|
Kitchen
|
50
|
50
|
60
|
|
(1) May be combined
|
| |
|
|
|
|
|
FOR
EACH SLEEPING ROOM*
|
|
Area
Of Room In Sq. Ft.
|
#
Of Persons
|
|
Less than 70 or any kitchen, hall, or
public space
|
May not be used as a sleeping room
|
|
70 to 99
|
1 Occupant
|
|
100 to 149
|
2 Occupants
|
|
150 to 199
|
3 Occupants
|
|
200 & Above
|
4 Occupants plus 1 for each
additional 50 sq. ft.
|
|
* Sleeping rooms must have proper
emergency egress
|
Who
can I call for more information?
Call the Building Commissioner’s Office
at 822-5823, Monday through Friday, 8 a.m. to 5 p.m.
Online Application Forms
Print off the PDF file below to make your
application process easier once you arrive at City Hall.
Property Maintenance Inspection Application
Home
Occupation Application
|